Skip to content
MS White Matter edit

Semi-automatic detection of increased susceptibility in multiple sclerosis white matter lesions imaged with 1.5T MRI

By: Karen Holzberger, President & CEO of SpinTech MRI

Author(s): L. Pelizzari a, N. Bergslanda,b, D. Utriainenc,d,e, S. Viotti a, F. Baglioa, L. Mendozzi a, P. Cecconi a, E.M. Haackec,d,f , P. Zamboni g, M.M. Laganàa,∗
Journal: Biomedical Signal Processing and Control
Published: 2020
Read Full Paper: https://www.sciencedirect.com/science/article/abs/pii/S1746809420301993

Abstract

MS White Matter

The identification of regions of increased susceptibility (RoIS) in multiple sclerosis (MS) white matter lesions (WML) is currently performed by the radiologist’s visual inspection of magnetic resonance imaging (MRI) data acquired with high-field MRI scanners. The aims of this study were: 1) to define and validate a semi-automatic method for detecting RoIS in WML from quantitative susceptibility maps (QSM) and susceptibility-weighted imaging (SWI) acquired with a 1.5 T MRI scanner; 2) to assess the prevalence of WML with RoIS and the susceptibility in those areas; and 3) to test the association between RoIS in WML and clinical outcomes.

Method

Thirty-eight MS patients were scanned on a 1.5 T MRI scanner. T2-hyperintense WML were segmented and superimposed on SWI and QSM images. Two intensity thresholds were defined and consecutively applied for identifying RoIS within WML (thrhyper_QSM to identify QSM hyperintensity within WML and thrhypoSWI to identify SWI hypointensity within WML). The sensitivity and specificity were assessed on a subgroup of subjects. The numbers of WML with RoIS and RoIS volume were determined. Differences between phenotypes and correlations with clinical outcome were tested.

Results

The method showed good sensitivity (95.6%) and specificity (92.1%). On average, 44.7% of the WML showed RoIS, occupying 11.0% of the total lesion volume, with an average susceptibility of 39.4 ± 12.2 ppb. The number of WML with RoIS was negatively correlated with disease duration (r = −0.342, p = 0.035).

Conclusions

The proposed semi-automatic method proved to be suitable for the detection of RoIS in WML at 1.5 T. This approach may be useful in longitudinal studies aiming to monitor susceptibility in WML.

Contact Us

SpinTech MRI

30200 Telegraph Rd., Suite 140
Bingham Farms, MI 48025

Email: info@spintechmri.com

Tel: +1 (248) 712 6789